Revit to SCIA: not enough analytical curves to create 2D member

Details of Revit to SCIA: not enough analytical curves to create 2D member

  • Module code ESA1934
  • Software
    • SCIA Engineer
  • FAQ topic

During the export of a Revit model to SCIA Engineer via the Revit to SCIA plugin, the following warning can pop up for a wall or plate: "not enough analytical curves to create 2D member in SCIA Engineer".

This warning will pop up when something is wrong with the geometry a specific plate. If you cannot find the element causing the issue, export only a specific selection to locate the element causing an issue. Review the geometry of this member by checking the boundaries. In most cases, the boundary is not closed or there are two nodes too close to each other.